Ford Ecosport: Intake Air Distribution and Filtering - 2.0L Duratec-HE (129kW/175PS) / Removal and Installation - Air Cleaner
Removal
NOTE:
Removal steps in this procedure may contain installation details.
-
-
Loosen the clamp and disconnect the MAF sensor electrical connector.
Torque:
35 lb.in (4 Nm)
-
Disconnect the air cleaner inlet tube.
-
Remove the Isolator screw.
Torque:
18 lb.in (2 Nm)
-
Disconnect the resonator pipe and remove the air cleaner assembly.
-
NOTICE:
Clean, inspect and cover all open ports.
Installation
-
To install, reverse the removal procedure.
Diagnostic Trouble Code (DTC) Chart
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation)...
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Disconnect and position aside the vent tube...
Other information:
Special Tool(s) /
General Equipment
Electronic Leak Detector
Inspection
NOTE:
Use a Rotunda-approved Electronic Leak Detector for R-1234yf refrigerant SAE Certified to J2913.
NOTE:
Good ventilation is necessary in the area where electronic A/C
leak testing is to be carried out...
B1142:62, B11D9:13, B13BF:14
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The BECMB provides battery voltage to the RCM and OCSM . The BECMB
compares HS-CAN1 messages to ignition voltage inputs...