Ford Ecosport: Intake Air Distribution and Filtering - 2.0L Duratec-HE (129kW/175PS) / Removal and Installation - Air Cleaner Outlet Pipe
Removal
NOTE:
Removal steps in this procedure may contain installation details.
-
-
Disconnect and position aside the vent tube.
-
Loosen the clamps, disconnect and remove the air cleaner outlet pipe.
Torque:
35 lb.in (4 Nm)
Installation
-
To install, reverse the removal procedure.
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Loosen the clamp and disconnect the MAF sensor electrical connector...
Other information:
Removal
Open the liftgate.
Remove the liftgate strut.
Installation
To install, reverse the removal procedure.
..
Removal
NOTE:
The evaporative emission blocking valve is serviced with the fuel tank pressure sensor and tube.
With the vehicle in NEUTRAL, position it on a hoist.
Refer to: Jacking and Lifting - Overview (100-02 Jacking and Lifting, Description and Operation).
Detach the retainer & remove the EVAP blocking valve electrical connector.
..