Ford Ecosport: Intake Air Distribution and Filtering - 2.0L Duratec-HE (129kW/175PS) / Removal and Installation - Air Cleaner Outlet Pipe
Removal
NOTE:
Removal steps in this procedure may contain installation details.
-
-
Disconnect and position aside the vent tube.
-
Loosen the clamps, disconnect and remove the air cleaner outlet pipe.
Torque:
35 lb.in (4 Nm)
Installation
-
To install, reverse the removal procedure.
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Loosen the clamp and disconnect the MAF sensor electrical connector...
Other information:
Removal
NOTE:
LH side shown, RH side similar.
Remove the rear door glass run and bracket.
Refer to: Rear Door Glass Run and Bracket (501-11 Glass, Frames and Mechanisms, Removal and Installation).
Remove the rear door glass top run.
Refer to: Rear Door Glass Top Run (501-11 Glass, Frames and Mechanisms, Removal and Installation).
..
Inspection
NOTE:
Procedure 1 — Ambient Temperature between 21°C (70°F) and 38°C (100°F)
NOTE:
Variable compressors may not stroke up unless the ambient
temperatures are above 21°C (70°F) when conducting the pressure mapping
procedure. Variable compressor need to see a thermal load on the system
in order to create normal operating pressures.
Run the engine ..