Ford Ecosport: Intake Air Distribution and Filtering - 2.0L Duratec-HE (129kW/175PS) / Removal and Installation - Air Cleaner Outlet Pipe
Removal
NOTE:
Removal steps in this procedure may contain installation details.
-
-
Disconnect and position aside the vent tube.
-
Loosen the clamps, disconnect and remove the air cleaner outlet pipe.
Torque:
35 lb.in (4 Nm)
Installation
-
To install, reverse the removal procedure.
Removal
NOTE:
Removal steps in this procedure may contain installation details.
Loosen the clamp and disconnect the MAF sensor electrical connector...
Other information:
Install the new input seal RH .
Refer to: Transfer Case Input Shaft Seal RH (308-07B Transfer Case -
6-Speed Automatic Transmission – 6F35, Removal and Installation).
Install the PTU and the PTU mounting bolts.
Torque:
59 lb.ft (80 Nm)
Install the engine mounting bracket and bolts.
Torque:
35 lb.f..
Special Tool(s) /
General Equipment
Interior Trim Remover
Removal
NOTE:
8 inch display is shown, all other displays are similar.
Release the clips and remove the screw cover trim panel.
Use the General Equipment: Interior Trim Remover
Remove the screws.
..