Ford Ecosport: Body and Paint / Front End Sheet Metal Repairs
Special Tool(s) /
General Equipment
Resistance Spotwelding Equipment
8 mm Drill Bit
MIG/MAG Welding Equipment
Spot Weld Drill Bit
Locking Pliers
Materials
Name
Specification
Seam SealerTA-2-B, 3M™ 08308, LORD Fusor® 803DTM
-
Removal
NOTE:
Factory welds may be substituted with resistance or metal
inert ga..
Other information:
B00D5:11, B00D5:12 and B00D5:13
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM briefly activates each LED in the PAD indicator to prove-out
and verify correct functional operation of the PAD indicator to the
occupants.
The RCM monitors the PAD indicator power supply and "OFF" LED circuits for the follo..
B1405:11, B1405:12, B1405:13, B1405:1A
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM continuously monitors the driver side air curtain circuits for the following faults:
Resistance out of range
Unexpected voltage
Short to ground
Faulted driver side air curtain
If a f..