Ford Ecosport: Starting System - 2.0L Duratec-HE (129kW/175PS) / Specifications
General Specifications
|
Item
|
Specification
|
|
Normal engine cranking speed
|
200-220 RPM
|
|
Starting circuit maximum voltage drop (Engine at normal operating temperature)
|
0.5 volt
|
|
Starter motor maximum load current draw
|
710 amps
|
|
Starter motor no-load current draw
|
60-75 amps
|
|
Starter motor normal load current draw
|
250 amps
|
Starting System
The starting system controls the cranking of the engine. The
PCM energizes the starter relay when it receives inputs from the
ignition switch, automatic transmission, and the BCM ...
Other information:
B1404:11, B1404:12, B1404:13, B1404:1A
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM continuously monitors the driver side airbag circuits for the following faults:
Resistance out of range
Unexpected voltage
Short to ground
Faulted driver side airbag
If a fault is d..
Special Tool(s) /
General Equipment
205-153
(T80T-4000-W)
Handle
307-626Installer, Differential SealTKIT-2008ET-FLMTKIT-2008ET-ROW
Puller
Punch
Removal
Remove the LH halfshaft.
Poke a small hole in the halfshaft seal.
Use the General Equipment: Punch
..