Ford Ecosport: Starting System - 2.0L Duratec-HE (129kW/175PS) / Specifications
General Specifications
|
Item
|
Specification
|
|
Normal engine cranking speed
|
200-220 RPM
|
|
Starting circuit maximum voltage drop (Engine at normal operating temperature)
|
0.5 volt
|
|
Starter motor maximum load current draw
|
710 amps
|
|
Starter motor no-load current draw
|
60-75 amps
|
|
Starter motor normal load current draw
|
250 amps
|
Starting System
The starting system controls the cranking of the engine. The
PCM energizes the starter relay when it receives inputs from the
ignition switch, automatic transmission, and the BCM ...
Other information:
The roof opening panel motor must be initialized when repairs
are carried out on any part of the roof opening panel system or when
the roof opening panel motor, glass, assembly, or air deflector has been
removed or replaced for any reason.
REFER to: Power Roof Opening Panel Initialization (501-17 Roof Opening Panel, General Procedures)...
B1415:11, B1415:12, B1415:13, B1415:96, B1418:11, B1418:12, B1418:13, B1418:96
Refer to Wiring Diagrams Cell 46 for schematic and connector information.
Normal Operation and Fault Conditions
The RCM monitors the passenger front door and driver C-pillar side impact sensor circuits for the following faults:
Open circuit
Short to voltage
Short to ground
..