System Operation

System Diagram


Item Description
1 RKE Antenna
2 Passive Key
3 With Push-Button Start
4 RKE Commands
5 BCM
6 IKT Key
7 Without Push-Button Start
8 RKE Commands
9 Passive Entry Commands
10 Rear Passenger Door Lock Control Switch With Indicator
11 If Equipped
12 DDM
13 DRDM
14 GWM
15 DLC
16 IPC
17 PDM
18 PRDM
19 Front Passenger’s Door Lock Control Switch With Indicator
20 With Passenger Door One-Touch Windows
21 Turn Signals
22 Horn
23 LF Door Handle
24 RF Door Handle
25 Tailgate
26 RR Door Latch
27 Door Latch Lock/Unlock Switch
28 Lock Actuator
29 Ajar Switch
30 Tailgate Latch
31 Door Latch Lock/Unlock Switch
32 Lock Actuator
33 Ajar Switch
34 Front Passenger Door Latch
35 Door Latch Lock/Unlock Switch
36 Lock Actuator
37 Ajar Switch
38 LR Door Latch
39 Door Latch Lock/Unlock Switch
40 Lock Actuator
41 Ajar Switch
42 Driver Door Latch
43 Door Latch Lock/Unlock Switch
44 Lock Actuator
45 Ajar Switch
46 Ignition Switch
47 Hood Ajar Switch
48 Driver’s Door Lock Control Switch With Indicator
49 Driver Door Lock Cylinder
50 Courtesy Lamps
51 Intrusion Sensor

Network Message Chart

  Module Network Input Messages - BCM


Broadcast Message Originating Module Message Purpose
Door lock switch status   DDM Used by the BCM to arm the perimeter alarm.
Door lock switch status   PDM Used by the BCM to arm the perimeter alarm.

  Module Network Input Messages - IPC


Broadcast Message Originating Module Message Purpose
Perimeter alarm chime request   BCM
  • Used by the IPC to sound the perimeter alarm chime during the 12 second delay.
  • Used by the IPC to sound the perimeter alarm chime immediately (South Africa only).

CAN Protection Strategy

When the perimeter alarm is armed, the BCM monitors the CAN . If a scan tool is connected to the DLC , and an attempt is made to establish a session with the BCM , it activates the perimeter alarm.

Every time the BCM detects an unauthorized access (alarm activates), all BCM programming, PID monitoring and self-test sessions are blocked for 10 minutes. At the end of the 10 minute time period, the traffic horn chirps to indicate the 1 minute of opportunity to communicate with the BCM and program keys if none are available. For vehicles without push button start,
Refer to: Anti-Theft Key Programming - Scan Tool (419-01B Passive Anti-Theft System (PATS) - Vehicles Without: Keyless Entry and Push Button Start, General Procedures).
For vehicles with push button start,
Refer to: Anti-Theft Key Programming - Scan Tool (419-01C Passive Anti-Theft System (PATS) - Vehicles With: Keyless Entry and Push Button Start, General Procedures).

Perimeter Alarm

The BCM controls the operation of the perimeter alarm. It monitors inputs from the RKE system, the passive entry system (if equipped), the power door lock system, the PATS and the ignition status to determine when to arm the perimeter alarm.

The BCM monitors all of the door ajar switches, the hood ajar switch, the CAN and the ignition status to determine when to activate the perimeter alarm. When the BCM detects an input indicating an unauthorized entry into the vehicle, the BCM activates the perimeter alarm by sounding the horn and flashing all the turn signals and interior courtesy lamps at regular intervals.

The BCM monitors the RKE system, the passive entry system (if equipped), and the PATS to determine when to disarm the perimeter alarm.

Perimeter Alarm Arming

The perimeter alarm is ready to arm any time the ignition is off. The perimeter alarm pre-arms when any of the following actions are performed:

  • Pressing the lock button on a RKE transmitter
  • Touching the outside region of the LHF or RHF door handle (if equipped with the passive entry feature)

Once the system is pre-armed, there is a 20 second countdown before the perimeter alarm is armed. Each entry point to the vehicle (hood, door and tailgate) is armed separately and must be closed before that entry point begins the 20 second countdown to become armed. If all entry points are closed, the turn signals flash upon locking indicating that all entry points are entering the 20 second countdown.

Perimeter Alarm Activation

The perimeter alarm has a 12 second delay when the driver front door is opened without using a RKE transmitter or a passive key (if equipped) to unlock the vehicle. During the delay, a chime sounds. If the perimeter alarm is not disarmed within the 12 second delay, the alarm activates.

The perimeter alarm activates when any of the following actions are performed:

  • The driver front door is opened without first receiving an unlock command from the passive entry feature (if equipped) or a programmed RKE transmitter, and the 12 second delay has expired.
  • Any other door, or the hood is opened without first receiving an electronic unlock command from the passive entry feature (if equipped) or a programmed RKE transmitter.
  • The ignition transitions to RUN without a valid PATS key read received.
  • The BCM detects an attempt by a diagnostic scan tool to establish communication on the CAN .

The perimeter alarm only activates 10 times per arming cycle. After that, the alarm does not activate. To enable the perimeter alarm again, disarm and arm it again.

Perimeter Alarm Activation (South Africa only)

The perimeter alarm is activated immediately when the driver front door is opened without using a RKE transmitter or a passive key (if equipped) to unlock the vehicle.

The perimeter alarm activates when any of the following actions are performed:

  • The driver front door is opened without first receiving an unlock command from the passive entry feature (if equipped) or a programmed RKE transmitter.
  • Any other door, or the hood is opened without first receiving an electronic unlock command from the passive entry feature (if equipped) or a programmed RKE transmitter.
  • The ignition transitions to RUN without a valid PATS key read received.
  • The BCM detects an attempt by a diagnostic scan tool to establish communication on the CAN .

The perimeter alarm only activates 10 times per arming cycle. After that, the alarm does not activate. To enable the perimeter alarm again, disarm and arm it again.

Perimeter Alarm Disarming

The perimeter alarm disarms when any of the following actions are performed:

  • Pressing the unlock button on a door lock control switch within the 20 second pre-arm
  • Pressing the unlock button on a programmed RKE transmitter
  • Using a programmed key to change the ignition to RUN
  • Unlocking a front door or the tailgate using the passive entry feature (if equipped)

Component Description

BCM

The BCM controls the operation of the perimeter alarm. Based on input, the BCM arms, disarms, activates or deactivates the perimeter alarm.

The BCM requires PMI when replaced. Additionally, at least 2 keys must be programmed and the parameter reset procedure carried out.

Door Ajar Switch

The door ajar switch is a single pole switch monitored by the BCM . The primary function of the door ajar switch is used for the courtesy lamps system.
Refer to: Interior Lighting - System Operation and Component Description (417-02 Interior Lighting, Description and Operation).

Door Latch

The door ajar switch, lock/unlock solenoid, and lock/unlock status input switch are part of the door latch and not serviceable separately.

The door ajar switch is monitored by the BCM and the primary function is for the courtesy lamps system.
Refer to: Interior Lighting - System Operation and Component Description (417-02 Interior Lighting, Description and Operation).

The lock/unlock solenoid is controlled by the BCM for locking and unlocking the door.
Refer to: Handles, Locks, Latches and Entry Systems - System Operation and Component Description (501-14 Handles, Locks, Latches and Entry Systems, Description and Operation).

Hood Ajar Switch

The hood ajar switch is a single pole switch (integrated into the hood latch) that is normally closed when the hood is closed. When the hood is opened, the hood ajar switch opens to indicate an open hood.

The BCM sends a voltage signal to the hood ajar switch, and based on the input, the BCM determines if the hood is open or closed.

Intrusion Sensor

The intrusion sensor is powered at all times and is monitored by the BCM . When the perimeter alarm is armed, the intrusion sensor monitors the passenger compartment for movement and, if movement is detected, it sends a signal to the BCM .

When the intrusion sensor is replaced, the BCM configuration must first be uploaded into a diagnostic scan tool, a new intrusion sensor installed, and then the BCM configuration downloaded back into the BCM for the new intrusion sensor to operate correctly.

    Description and Operation - Perimeter Anti-Theft Alarm - Overview

    Overview The perimeter anti-theft alarm system has three operation modes: ARMED - The perimeter anti-theft alarm is armed when the ignition is OFF and all vehicle entry points have been electrically locked for 20 seconds...

    Diagnosis and Testing - Perimeter Anti-Theft Alarm

    DTC Chart: BCM Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation)...

    Other information:

    Ford Ecosport 2014-2026 Service and Repair Manual: Description and Operation - Wheel and Tire Health and Safety Precautions


      WARNING: Never inflate a tire that has been run flat without first removing the tire from the wheel to inspect for damage. A damaged tire can fail during inflation. Failure to follow this instruction may result in serious personal injury...

    Ford Ecosport 2014-2026 Service and Repair Manual: Description and Operation - Starting System - System Operation and Component Description


    System Operation System Diagram Item Description 1 PCM 2 Starter relay 3 Starter motor 4 BCM 5 Automatic transmission 6 Ignition switch Network Message Chart   Module Network Input Messages Powertrain Control Module (PCM) ..

    Categories

    Removal and Installation - Oil Pressure Switch

    Materials

    Name Specification Motorcraft® Thread Sealant with PTFE
    TA-24-B WSK-M2G350-A2
     

    Removal

    NOTE: Removal steps in this procedure may contain installation details.

    With the vehicle in NEUTRAL, position it on a hoist.
    Refer to: Jacking and Lifting - Overview (100-02 Jacking and Lifting, Description and Operation).
    If equipped, remove the bolts and the underbody shield.